Construction drawings are the detailed set a builder prices and builds from: dimensions, junction details, stairs, windows, insulation and services, drawn so nothing is left to guesswork on site. We prepare them for London homes. Fixed quote after a free constraints check.

Fixed quote after a free constraints check

  • MCIAT chartered
  • £2m PI insured
  • LABC Partnered
  • Fixed fees, VAT included

Request a fixed quote

We use it to check conservation areas and constraints.
Pick the council that decides your application.
A few lines: what you want to build, and anything the council has already said.
Add photos or drawings

Drop files here or choose from your device

PDF, JPG, PNG, DWG · up to 10 files, 90 MB in total

    Brick house being extended, with a wide new opening supported over the ground floor

    Why construction drawings matter after planning

    Planning drawings win permission. They show the shape of the building, not how it is made. A builder cannot order bricks, set out a staircase or fix a window from them, and two builders pricing from the same planning set will quote very different sums, because each fills the gaps differently.

    Construction drawings close the gaps. They fix the wall build-up, the floor levels, the opening sizes, the stair, the roof and the services, so every contractor prices the same building. That is why they are the most useful drawings for controlling cost.

    They also carry the Building Regulations information, so one set can serve both the builder and building control.

    The costliest guesses on site are usually junctions and finishes. A drawing that names the product and the fixing removes the guess, and with it the allowance a cautious contractor adds to cover the risk.

    House extension under construction with scaffolding, new glazed doors and building materials

    Stairs, headroom and the geometry that gets checked

    Stairs are where a design is most easily caught out. For a private stair, Approved Document K sets limits on rise, going and pitch. The rise and going ranges, the maximum pitch and the formula that links them are in the table.

    Headroom is the other constraint. Approved Document K expects clear height over the stair, and in a loft it is the stairwell, not the room, that often decides where the stair can land. We draw the stair in section against the roof before the layout is frozen.

    A stair that fails these numbers will be marked up by building control, and moving it on site costs far more than moving it on paper.

    We also draw handrail and balustrade heights and the landings at top and bottom, because the examiner checks the whole stair, not only the flights.

    Escape routes, fire detection and ventilation

    Fire safety shows up in the drawings in practical ways. Where a loft or first-floor room is a bedroom, an escape window must have a minimum clear opening and a limited sill height. The measurements are in the table. All dwellings need mains-operated smoke alarms to a stated grade and category.

    Ventilation is drawn in as extract rates for kitchens, utilities, bathrooms and WCs, and as background ventilation to habitable rooms. We note the fan capacities so the electrician and builder install what the examiner expects.

    Our building regulations drawings page explains how these requirements are submitted for approval.

    Insulation and U-values on new elements

    New walls, roofs, floors, windows and doors in an existing home must meet limiting U-values, which cap how much heat each element loses. The table lists each limit from Approved Document L, and the specification on our sheets names a build-up that meets them.

    Meeting the number is a design choice with consequences. A thicker roof build-up changes the ridge height, which may matter for planning. A better window changes the cost. We resolve those trade-offs before the set is issued, so the price your builder gives is the price you pay.

    Where a project needs an energy assessment, our SAP calculations service coordinates it.

    Materials, workmanship and who carries the duties

    The materials and workmanship Approved Document sets the standard for products and site work, and our specification refers to it. It means a builder cannot substitute an unsuitable product without it showing up as a departure from the drawings.

    Under the Part 2A rules, a domestic client's duties pass to the contractor or principal contractor. Our handover notes summarise this, so you know what your builder takes on. For larger or riskier jobs, our Principal Designer service covers the design-side duties.

    How we produce the set

    The set grows from the approved model. We add the structure, the services and the details, and derive the plan layouts, cross-sections and elevations from the same model, so they agree. Our structural calculations feed the beam and foundation sheets directly.

    Every sheet is checked by a second technologist before issue, and a senior review signs off the set. A first issue normally follows the survey within about a week. If the council or building control wants amendments, we revise them without charge.

    The national rules in figures

    Figures with their unit, period and source
    MeasureValuePeriodSource
    Approved Document K 2013, para 1.3, Table 1.1Private stair: rise 150-220 mm, going 220-300 mm, max pitch 42°, 2R+G 550-700 mm—gov.uk
    Approved Document K 2013, para 1.11, Diagram 1.32.0 m clear headroom over stairs—gov.uk
    Approved Document B Vol 1, 2019 ed. incl. 2026 amendments, para 2.10Escape window: unobstructed openable area at least 0.33 m², at least 450 mm high and 450 mm wide, bottom of opening no more than 1100 mm above floor—gov.uk
    Approved Document B Vol 1, paras 1.1-1.2All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604—gov.uk
    Approved Document L Vol 1 2021 incl. 2023 amendments, Table 4.2New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4—gov.uk
    Approved Document F Vol 1 2021, Table 1.1Intermittent extract: kitchen 30 l/s with cooker hood (60 l/s otherwise), utility 30 l/s, bathroom 15 l/s, WC 6 l/s—gov.uk
    AD 7 (regulation 7)Approved Document 7: Materials and workmanship, 2013 edition incorporating 2018 amendments—gov.uk
    Building Regulations 2010 reg 11C(1)For a domestic client, the client's Part 2A duties pass to the contractor (or principal contractor)—legislation.gov.uk

    A blank value means the figure has not been published, not that there are none. Check your own address with the council.

    Building regulations, layer by layerPart A: structure: Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments. Part B: fire safety: All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604. Part L: insulation: New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4. Part K: stairs: 2.0 m clear headroom over stairs. Full plans application: Building control body must decide a full plans application within 5 weeks, or longer if agreed in writingPart A: structurePart B: fire safetyPart L: insulationPart K: stairsFull plans applicationABCDE

    Building regulations, layer by layer

    The Approved Documents that shape most house projects, from structure to the application itself.

    A · Part A: structure
    Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments
    B · Part B: fire safety
    All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604
    C · Part L: insulation
    New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4
    D · Part K: stairs
    2.0 m clear headroom over stairs
    E · Full plans application
    Building control body must decide a full plans application within 5 weeks, or longer if agreed in writing

    What you receive

    Building regulations section drawing showing the construction build-up
    Sample drawing. Building regulations section showing construction build-up for a building control check.
    Pencil resting on a dimensioned technical drawing beside a scale rule
    Every layer specified
    Move across to open the layers; move down to pick one.

    Questions

    What is the difference between planning drawings and construction drawings?

    Planning drawings show the shape and appearance of the building for the council. Construction drawings show how it is made, in enough detail for a builder to price and build.

    Do I need construction drawings to get building regulations approval?

    Building control needs technical information on structure, insulation, fire safety and drainage. Construction drawings carry it, and can serve your contractor and building control alike.

    How much do construction drawings cost?

    Fixed quote after a free constraints check. The price depends on the size and complexity of the project.

    Do the drawings cover stairs?

    Yes. We draw the stair against the rise, going, pitch and headroom limits in Approved Document K, in plan and section.

    Can my builder start from planning drawings alone?

    They can, but each builder will fill the gaps differently, so quotes vary widely. A construction set lets every builder price the same building.