Building regulations

SAP calculations in London

A SAP calculation is the energy assessment a building control body may ask for when a London home is extended or newly built. We coordinate it with an assessor and fit it to your drawings, for a fixed quote after a free constraints check, VAT included. Many extensions can meet the energy rules without one, so the first job is to find out which route your project takes.

Fixed quote after a free constraints check

  • MCIAT chartered
  • £2m PI insured
  • LABC Partnered
  • Fixed fees, VAT included

Request a fixed quote

We use it to check conservation areas and constraints.
Pick the council that decides your application.
A few lines: what you want to build, and anything the council has already said.
Add photos or drawings

Drop files here or choose from your device

PDF, JPG, PNG, DWG · up to 10 files, 90 MB in total

    House extension under construction with scaffolding, new glazed doors and building materials

    When a SAP calculation is needed

    SAP stands for Standard Assessment Procedure. It is a method for rating how much energy a dwelling uses, and building control reads the result against Part L of the Building Regulations. For a new home it is part of the normal submission. For an extension it is one of several ways to prove compliance, and often not the one you need.

    The deciding question is how much of the new building is glass and how well each element holds its heat. A plain brick extension with modest windows usually passes on simple limits. An extension with a wall of glazing, or a design that cannot meet the individual limits, is where a calculation earns its fee.

    Because the answer depends on the design, we ask for it early. Raising it after the plans are frozen is how a small energy question turns into a redraw.

    Pencil resting on a dimensioned technical drawing beside a scale rule

    The three ways an extension can comply

    Approved Document L sets out the routes. The first is the elemental route, where every new part of the building meets a limiting U-value. For new elements in existing homes the document states: New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4.

    Glazing has its own cap on that route. The guidance says: Windows, roof windows, rooflights and doors in an extension should not exceed 25% of the extension floor area plus the area of openings removed or covered. A kitchen extension with large sliding doors can pass that cap easily or miss it badly, so we count the openings on the drawings before anyone orders a door.

    When the elemental limits do not fit the design, the guidance offers two alternatives: Alternative routes: area-weighted U-value (para 10.9) or a SAP calculation against a notional extension (para 10.10). The SAP route compares your extension against a notional one of the same shape. It gives the designer room to trade, for example a little more glass against a better roof.

    We choose the route with you at the drawing stage, because the build-up of walls, roof and floor on the sheets must match whatever the calculation assumes.

    New homes and the changing energy rules

    A new dwelling is assessed differently from an extension, and the method is changing. For new dwellings AD L 2026 names two methods: the Home Energy Model (HEM) and SAP; validity dates are in the Notice of Approval. If you are planning a new house, a conversion into flats or a large replacement home, your assessor needs to know which edition applies on the day your building notice or full plans are deposited.

    The start date is set out in the guidance itself: AD L 2026 takes effect 24 Mar 2027 (24 Sep 2027 for higher-risk building work). Projects already in the system are covered by the transitional rule: AD L/F 2021 continue where plans/notices are deposited before 24 Mar 2027 and work starts before 24 Mar 2028.

    In plain terms, the date you deposit plans and the date work starts both matter. We note both on the programme we give you, so the energy edition is never a surprise halfway through the build.

    For a new build, our new build drawings and the energy work are planned together, because insulation thickness and window sizes change the wall and roof sections.

    Overheating and the energy performance certificate

    Energy use is only half the story. Modern, well-insulated homes can run hot, so the Building Regulations also look at summer comfort. The relevant document is plain: Approved Document O (overheating) applies to new residential buildings. For a large glazed extension on a south-facing garden, expect the assessor to ask about shading and opening areas.

    A new home also needs an energy performance certificate once built, which is a separate document from the design-stage calculation. The rule reads: An energy performance certificate is required on construction of a new dwelling.

    Think of the calculation as the prediction and the certificate as the record. If the two disagree on site, because the builder swapped a window or thinned the insulation, the certificate can come out worse than the design promised. We keep the specification on the drawings for that reason.

    How SAP fits with the rest of your drawings

    A SAP result is only as good as the information fed into it: floor areas, wall and roof types, window sizes and heating. All of those come from your drawings, so we prepare the data from the same model that produces the plans. That avoids the common problem where the assessor measures from a rough sketch and the figures never match the building.

    The calculation sits beside, not instead of, the technical package. Our building regulations drawings show the construction details, and structural calculations cover the beams and foundations. For a full set of working sheets, see our construction drawings.

    If you want a second opinion on an existing design before ordering anything, our independent drawing review reads the set against the rules and flags energy risks early.

    Cost, timing and who does the calculating

    We do not publish a standard price for SAP, because the work ranges from a short check on an extension to a full assessment of a new dwelling. You get a fixed quote after a free constraints check, VAT included, before you commit to anything.

    The calculation is carried out by an assessor we coordinate, working from our model. You deal with one point of contact, and the energy figures come back in time for the building regulations submission.

    Drawings are normally ready about a week after the survey, and the energy information follows the design freeze rather than holding it up. Send us the address and a short brief to start.

    Where we prepare energy information

    Every council runs the same national energy rules, but its building control team and local planning conditions shape what is asked for. Our council pages set out the local picture, and you can find yours under architectural drawings by area.

    Extending to the rear, side or loft? Start with the matching drawings page, such as rear extension drawings or loft conversion drawings, and ask us to include the energy route in the first design review.

    The national rules in figures

    Figures with their unit, period and source
    MeasureValuePeriodSource
    Approved Document L Vol 1 2021 incl. 2023 amendments, Table 4.2New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4—gov.uk
    Approved Document L Vol 1 2021, para 10.7(d)Windows, roof windows, rooflights and doors in an extension should not exceed 25% of the extension floor area plus the area of openings removed or covered—gov.uk
    Approved Document L Vol 1 2021, paras 10.9-10.10Alternative routes: area-weighted U-value (para 10.9) or a SAP calculation against a notional extension (para 10.10)—gov.uk
    AD L Vol 1 2026, regulation 24 intention (p.11)For new dwellings AD L 2026 names two methods: the Home Energy Model (HEM) and SAP; validity dates are in the Notice of Approval—gov.uk
    AD L Vol 1 2026, p.2AD L 2026 takes effect 24 Mar 2027 (24 Sep 2027 for higher-risk building work)—gov.uk
    Circular 01/2026 (transitional arrangements)AD L/F 2021 continue where plans/notices are deposited before 24 Mar 2027 and work starts before 24 Mar 2028—gov.uk
    Approved Document O 2021, para 0.3Approved Document O (overheating) applies to new residential buildings—gov.uk
    Building Regulations 2010 notices referencing reg 7A of the Energy Performance of Buildings (England and Wales) Regulations 2012An energy performance certificate is required on construction of a new dwelling—legislation.gov.uk

    A blank value means the figure has not been published, not that there are none. Check your own address with the council.

    Building regulations, layer by layerPart A: structure: Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments. Part B: fire safety: All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604. Part L: insulation: New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4. Part K: stairs: 2.0 m clear headroom over stairs. Full plans application: Building control body must decide a full plans application within 5 weeks, or longer if agreed in writingPart A: structurePart B: fire safetyPart L: insulationPart K: stairsFull plans applicationABCDE

    Building regulations, layer by layer

    The Approved Documents that shape most house projects, from structure to the application itself.

    A · Part A: structure
    Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments
    B · Part B: fire safety
    All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604
    C · Part L: insulation
    New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4
    D · Part K: stairs
    2.0 m clear headroom over stairs
    E · Full plans application
    Building control body must decide a full plans application within 5 weeks, or longer if agreed in writing

    What you receive

    Building regulations section drawing showing the construction build-up
    Sample drawing. Building regulations section showing construction build-up for a building control check.
    Red-brick English house with rows of solar panels on its tiled roof
    Energy in
    Move the pointer up — the plug rises toward the socket.

    Questions

    Does every extension need a SAP calculation?

    No. An extension can comply by the elemental route, by an area-weighted U-value calculation or by a SAP calculation against a notional extension. The guidance puts it this way: Alternative routes: area-weighted U-value (para 10.9) or a SAP calculation against a notional extension (para 10.10).

    What U-values must a new extension meet?

    The limits for new elements in existing homes are: New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4. We put the matching wall, roof and floor build-ups on your drawings.

    Is there a limit on glazing in an extension?

    Yes, on the elemental route. The guidance says: Windows, roof windows, rooflights and doors in an extension should not exceed 25% of the extension floor area plus the area of openings removed or covered.

    Which energy rules apply to a new home this year?

    It depends on when plans are deposited and work starts. AD L/F 2021 continue where plans/notices are deposited before 24 Mar 2027 and work starts before 24 Mar 2028. We confirm the edition for your project in the first call.

    How much does a SAP calculation cost?

    Fixed quote after a free constraints check, VAT included. The price depends on whether it is a short extension check or a full new dwelling assessment.