Building regulations
Structural calculations in London
Structural calculations show that the beams, lintels, padstones and walls in your project are strong enough, and building control will ask for them. The fee opens at £295, VAT included, for London homes, with the figures matched to the drawings so the builder and the examiner read the same numbers.
From £295 (VAT included)
- MCIAT chartered
- £2m PI insured
- LABC Partnered
- Fixed fees, VAT included
Request a fixed quote

What structural calculations cover
Any opening you knock through a load-bearing wall needs a beam. Any loft conversion changes the loads on the floor below. Any extension adds a new foundation and roof. Structural calculations are the engineer's working that proves each element carries its load.
The output is a set of calculations and a sketch layout, giving each beam's size and grade, the padstones under it and the temporary support to use while it goes in. Building control reads them alongside the drawings.
They are not optional extras. The structure is the part of a building where an error costs most, and the Building Regulations require the design to be done by a competent person.

The rules behind the numbers
The relevant guidance is Approved Document A, which covers structure. It gives simple rules for common cases. For masonry walls in residential buildings of not more than three storeys, its wall-thickness rules apply. For floors supported by a wall, the simple rules cover a span of up to 6 metres between bearing centres.
Beyond the simple rules, calculation is the route. That means checking each member for bending, shear and deflection, and the bearing it sits on. The figures in the table show the scope and the limits we work to.
The design also has to resist disproportionate collapse, which sets how much robustness is needed.
The calculation also records the loads assumed for floors, roof and finishes, so a later change of roof covering can be tested against the original design.
Where a calculation is most often needed
Three jobs come up again and again: removing a chimney breast or a wall between rooms, forming a wide opening in a rear extension, and converting a loft. Each needs a beam or a new floor structure, and each needs the existing walls checked for the extra load.
In a loft the floor joists are rarely big enough for habitable use, so new joists or steel are designed. In a rear extension the large glazed opening is carried by a beam, and its end bearings carry point loads down to the foundation.
We pick these up in the survey, noting wall thicknesses and what is above and below each opening, so the calculation starts from facts instead of assumptions.
Existing walls matter as much as the new beam. We record whether a wall is solid brick or cavity, its thickness and any chimney stack above, because those details decide the loads that reach each bearing.
How our structural service works
We prepare the architectural drawings, set out the structural intent and coordinate the calculations with a structural engineer, so the structure is designed alongside the building rather than added after. The beams on our sheets are the beams in the calculation.
A change to an opening is made once in the Revit model and flows to every sheet. A technologist who did not draft it checks the set before it goes to building control, and the engineer's output is checked against it.
Our building regulations drawings use the calculations directly, and the complete package covers planning, building regulations and structural together.
Party walls and excavation near neighbours
Structural work often touches the boundary. Under the Party Wall etc. Act 1996 you must serve an adjacent excavation notice at least one month before work if you dig within a set distance of a neighbour's building and deeper than their foundations. The exact tests are in the table.
Our party wall notices service prepares the notices and the drawings that go with them. Serving them early avoids a dispute that stops the build.
If your project needs more than calculations, such as engineered design for a basement or a complex frame, our structural engineering page describes that wider service.
Price and what you receive
Structural calculations start at £295 including VAT, as a fixed fee confirmed after the constraints check. Larger or more complex structures are quoted from the same price list.
You receive the calculations, the beam and padstone schedule and a layout drawing. Expect the package roughly a week after the survey; if building control wants changes, we revise at no extra charge.
The national rules in figures
| Measure | Value | Period | Source |
|---|---|---|---|
| AD A title page | Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments | — | gov.uk |
| AD A para 2.1, Section 2C | Section 2C wall-thickness rules cover residential buildings of not more than three storeys | — | gov.uk |
| AD A para 2C23: max span of a floor supported by a wall, centre to centre of bearing | 6 m | — | gov.uk |
| AD A Section 5, Table 11 | Houses not exceeding 4 storeys are Consequence Class 1 for disproportionate collapse | — | gov.uk |
| Party Wall etc. Act 1996 s6(1), s6(2), s6(5) | Adjacent excavation notice at least 1 month before work: within 3 m and deeper than the neighbour's foundations, or within 6 m and cutting a 45° line from their foundations | — | legislation.gov.uk |
| Building Regulations 2010 reg 11F | Design work must be done by a competent person | — | legislation.gov.uk |
A blank value means the figure has not been published, not that there are none. Check your own address with the council.
Building regulations, layer by layer
The Approved Documents that shape most house projects, from structure to the application itself.
- A · Part A: structure
- Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments
- B · Part B: fire safety
- All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604
- C · Part L: insulation
- New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4
- D · Part K: stairs
- 2.0 m clear headroom over stairs
- E · Full plans application
- Building control body must decide a full plans application within 5 weeks, or longer if agreed in writing
What you receive


Where we prepare structural calculations
London
- Structural calculations in Barking and Dagenham
- Structural calculations in Bexley
- Structural calculations in Brent
- Structural calculations in Bromley
- Structural calculations in Camden
- Structural calculations in City of London
- Structural calculations in Westminster
- Structural calculations in Croydon
- Structural calculations in Ealing
- Structural calculations in Hackney
- Structural calculations in Haringey
- Structural calculations in Harrow
- Structural calculations in Havering
- Structural calculations in Hillingdon
- Structural calculations in Hounslow
- Structural calculations in Islington
- Structural calculations in Kensington and Chelsea
- Structural calculations in Kingston upon Thames
- Structural calculations in Lambeth
- Structural calculations in Lewisham
- Structural calculations in Merton
- Structural calculations in Newham
- Structural calculations in Redbridge
- Structural calculations in Richmond upon Thames
- Structural calculations in Southwark
- Structural calculations in Sutton
- Structural calculations in Tower Hamlets
- Structural calculations in Waltham Forest
- Structural calculations in Wandsworth
Questions
Do I need structural calculations for a beam?
Yes. Building control normally asks for calculations for any new beam or opening in a load-bearing wall, and the design must be done by a competent person.
How much do structural calculations cost?
Pricing begins at £295 including VAT, set in advance.
What does Approved Document A cover?
It is the government's practical guidance on structure for the Building Regulations. It gives simple rules for common cases and points to calculation for the rest.
Do I need a party wall notice for new foundations?
Possibly. An adjacent excavation notice is needed at least one month before work if you dig close to a neighbour's building and deeper than their foundations. We check this on the survey.
Who does the calculations?
We coordinate them with a structural engineer and check them against our drawings, so one set of numbers runs through every sheet.
Sources and dates
- gov.uk, retrieved
- legislation.gov.uk, retrieved
- legislation.gov.uk, retrieved
- gov.uk, retrieved
- gov.uk, retrieved
- gov.uk, retrieved
- legislation.gov.uk, retrieved
- Contains public sector information licensed under the Open Government Licence v3.0.
- Contains OS data © Crown copyright and database right 2026.
- Contains HM Land Registry data © Crown copyright and database right 2026. This data is licensed under the Open Government Licence v3.0.
- Contains Historic England data © Historic England 2026. Contains Ordnance Survey data © Crown copyright and database right 2026.

Tell us about your property.
We check the constraints, then send a fixed fee. Messages before 3pm get a reply the same working day.