Bexley, London

M&E drawings in Bexley

M&E drawings in Bexley are the lighting, power, ventilation and alarm sheets for a borough of family houses: 75.3 per cent of its 95,300 households live in one, and 68.6 per cent own it. We draw them into the same model as the plans, so a fitter and an electrician can price from one set. Fixed quote after a free constraints check.

Fixed quote after a free constraints check

  • MCIAT chartered
  • £2m PI insured
  • LABC Partnered
  • Fixed fees, VAT included

Request a fixed quote

We use it to check conservation areas and constraints.
Pick the council that decides your application.
A few lines: what you want to build, and anything the council has already said.
Add photos or drawings

Drop files here or choose from your device

PDF, JPG, PNG, DWG · up to 10 files, 90 MB in total

    Architectural model of a four-storey London stucco townhouse in its terrace, with a portico, area railings, sash windows, a cornice and chimney stacks
    The house as it stands: four storeys over a lower ground floor.Existing Proposed worksAn illustrative model, built for this page.

    How we work on m&e drawings

    Four steps from first call to approval.

    The same model cut through the middle: every floor, the stair, the chimney breasts, the new mansard, rear extension and basement in section
    Section through the model: every floor on one datum.
    1. Enquiry and constraints check

      We check the property against conservation areas, listed status, Article 4 directions, tree preservation orders, flood zone and planning history. We choose the right route and send a fixed quote.

    2. Measured survey

      We survey the house on one datum: rooms, levels, boundaries, drains, trees and the neighbours' windows that the 45° and 25° tests depend on.

    3. Building regulations

      Technical drawings are coordinated with the structural engineer's calculations, the drainage and the planning conditions.

    4. Approval and hand-over

      Building control approval, then a next-steps pack covering the commencement notice, party wall timing and CIL.

    Free redraws until approval. Every drawing set is checked independently, and the checker is never the person who drew it.

    Request a fixed quote
    House extension under construction with scaffolding, new glazed doors and building materials

    Bexley's energy and drainage rules for M&E drawings

    Bexley's rules bite mostly on larger schemes, and a householder should know where the line falls. The council's energy requirement is logged as majors only: an Energy Assessment for major developments, following the GLA's lean, clean, green order, with a district heating connection preferred where one is within reach. A house extension is not a major development, so no assessment is needed, but the same order is a sensible way to organise an M&E layout, with efficiency first and low-carbon supply second.

    Drainage has its own trigger. The council's SuDS rule applies to majors; non-householder in Vulnerable Drainage Area. For a house, that means a non-householder project, such as a new dwelling or a flat conversion, in a Vulnerable Drainage Area needs a strategy with greenfield run-off rates. An ordinary extension does not, and we say so at the quote stage.

    Two London Plan policies reach every borough, Bexley included. Mains water is limited to 105 l/p/d (+ up to 5 l external), and overheating is tackled through a cooling hierarchy, 6 steps. Our sheets mark each fitting against the first and show the fans and controls that serve the second.

    Brick house being extended, with a wide new opening supported over the ground floor

    Local figures for Bexley

    Figures with their unit, period and source
    MeasureValuePeriodSource
    Energy Assessment required for major developments, following the GLA energy assessment guidance and the lean-clean-green hierarchy, with district heating connection (including the Riverside Resource Recovery Facility network) prioritised.majors only—bexley.gov.uk, London Borough of Bexley Planning Application Requirements (reviewed 17 October 2018), pp.15-16, 'Energy Assessment'
    SuDS strategy required for all major applications and all non-householder applications with buildings or hard surfaces in a Vulnerable Drainage Area. It must follow the SuDS hierarchy, give greenfield run-off rates, and include a detailed site layout, topographical survey, SuDS plans, discharge calculations and maintenance details.majors; non-householder in Vulnerable Drainage Area—bexley.gov.uk, London Borough of Bexley Planning Application Requirements (reviewed 17 October 2018), p.27, 'Sustainable Urban Drainage Systems (SuDS) Strategy'
    London Plan Policy SI 5C(1): development proposals should, through planning conditions, limit mains water use to the Building Regulations optional requirement, 105 litres or less per head per day for residential development, excluding an allowance of up to 5 litres for external use. Applies in every London borough.105 l/p/d (+ up to 5 l external)—london.gov.uk, The London Plan 2021 (GLA, March 2021), p.356, Policy SI 5 part C(1)
    London Plan Policy SI 4B: major development must show through an energy strategy how internal overheating and reliance on air conditioning are reduced, following the six-step cooling hierarchy (reduce heat entering; minimise internal heat generation; manage heat with thermal mass; passive ventilation; mechanical ventilation; active cooling). Para 9.4.1 says the principles can also be applied to minor development.cooling hierarchy, 6 steps—london.gov.uk, The London Plan 2021 (GLA, March 2021), p.354, Policy SI 4 part B and para 9.4.1
    Households living in a house75.3 % of households living in a house or bungalow (detached, semi-detached or terraced)Census 2021nomisweb.co.uk
    Owner-occupied households68.6 % of households owner-occupied (owned outright or with mortgage/loan)Census 2021nomisweb.co.uk
    Householder applications granted94.6 %1 July 2025 - 30 June 2026assets.publishing.service.gov.uk
    Average price, semi-detached534,337 GBP2026-07publicdata.landregistry.gov.uk
    AD F Vol 1 (2021), Table 1.1 intermittent extract, PDF p.16; 2026 edition Table 1.115 l/s—gov.uk
    AD S (2021) para 6.2, PDF p.357 kW—gov.uk

    A blank value means the figure has not been published, not that there are none. Check your own address with the council.

    Councils bordering Bexley
    Building regulations, layer by layerPart A: structure: Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments. Part B: fire safety: All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604. Part L: insulation: New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4. Part K: stairs: 2.0 m clear headroom over stairs. Full plans application: Building control body must decide a full plans application within 5 weeks, or longer if agreed in writingPart A: structurePart B: fire safetyPart L: insulationPart K: stairsFull plans applicationABCDE

    Building regulations, layer by layer

    The Approved Documents that shape most house projects, from structure to the application itself.

    A · Part A: structure
    Approved Document A: Structure, 2004 edition incorporating 2004, 2010 and 2013 amendments
    B · Part B: fire safety
    All dwellings: fire detection and alarm system minimum Grade D2 Category LD3 (BS 5839-6), mains-operated smoke alarms to BS EN 14604
    C · Part L: insulation
    New elements in existing dwellings, limiting U-values W/(m²·K): roof 0.15, wall 0.18, floor 0.18, windows 1.4 (or WER Band B), doors 1.4
    D · Part K: stairs
    2.0 m clear headroom over stairs
    E · Full plans application
    Building control body must decide a full plans application within 5 weeks, or longer if agreed in writing

    Suburban houses and what their M&E needs

    Many of Bexley's houses are semis and terraces. The average semi sold for £534,337, a terrace for £416,198 and a detached house for £736,523, and prices moved 2 per cent in the last twelve months. Owners here are adding kitchens, loft rooms and garage conversions to homes they plan to stay in.

    Those jobs make the same demands on M&E. A garage conversion needs lighting, sockets, a heat source and extract fans where none existed, and the consumer unit may be a single board in the garage. A loft room needs its own circuit, a fire-detection link to the existing alarms and ventilation sized for the whole house. We draw each of those, with the circuit numbers and the route.

    The council's Design Guide SPD Part 2: Building Alterations and Extensions is the guide for how extensions look from outside, with Design Guide SPD Part 1: Design Principles behind it. We use it to keep flue and vent terminals to the rear or the side, where the design guide would put them.

    Extract rates, alarms and charge points

    Approved Document F sets intermittent extract at 15 litres per second in a bathroom, 30 in a utility room and 60 in a kitchen without a hood or with a recirculating one. The whole-dwelling rate for a three-bedroom house is 31.

    A carbon monoxide alarm is needed in the room where there is a new or replacement fixed solid fuel appliance in a dwelling (AD J para 2.34). The alarm standard is BS EN 50291-1:2018, and the ceiling position is at least 300 millimetres from the wall.

    Fixed lighting must reach 75 lumens per circuit watt now. Where a new dwelling has parking, the charge point must have a nominal output of at least 7 kW, and we show its position and the cable route.

    How the borough decides and what it holds

    Bexley decided 877 householder applications in its latest year, granted 94.6 per cent and decided 99.4 per cent in time. For larger home extensions through prior approval, the returns show 7 granted and 8 refused. The council also handled 323 lawful development certificate applications. These numbers help us plan the stage after planning and promise nothing about a case.

    Heritage constraints are light compared with inner London: 23 conservation areas and 114 listed buildings, with 6 at Grade I. About 17 per cent of the borough is Green Belt, and gardens cover 25.1 per cent of the land. The levy is zoned at £40/m² (Zone 1); £60/m² (Zone 2), plus indexation.

    Price, checking and related pages

    We do not publish a starting price for M&E drawings. After a free constraints check you get a fixed quote, and a second MCIAT technologist checks every sheet against the regulations and the architectural plans.

    The sheets go with the building regulations drawings in Bexley, the national M&E drawings page and MEP design in Bexley where heating and water are included. See architectural drawings in Bexley for the borough overview. Nearby, compare M&E drawings in Dartford, Bromley and Barking and Dagenham.

    What you receive

    Building regulations section drawing showing the construction build-up
    Sample drawing. Building regulations section showing construction build-up for a building control check.
    Pencil resting on a dimensioned technical drawing beside a scale rule
    Every layer specified
    Move across to open the layers; move down to pick one.

    Questions

    Does a Bexley house extension need an Energy Assessment?

    The council's requirement is logged as majors only, so an ordinary extension does not. We still follow the same order when laying out services.

    When does Bexley ask for a SuDS strategy?

    The rule applies to majors; non-householder in Vulnerable Drainage Area. A standard householder extension is outside it.

    What extract rate does a bathroom need?

    Approved Document F sets 15 litres per second for intermittent extract.

    How much do M&E drawings cost in Bexley?

    Fixed quote after a free constraints check. The price depends on the number of rooms and the systems.